Cell Logic Class II, Type A2 Biosafety Cabinets (BSCs) are engineered to provide exceptional protection for personnel, products, and the environment against hazardous particulates, including agents that require BSL 1-4 containment. These cabinets are specifically designed to cater to the needs of cell research, featuring a modified sash that accommodates microscopes and a temperature-controlled work area to ensure cell viability.
Versatile in design, these BSCs can exhaust HEPA-filtered air either into the laboratory or through an optional Ventus II Canopy Connection. When connected to a canopy, the Logic BSC is suitable for applications involving small quantities of volatile toxic chemicals and trace amounts of radionuclides.
Logic Class II, Type A2 Biosafety Cabinets (BSCs) deliver comprehensive protection for personnel, products, and the environment from hazardous particulates, including agents requiring BSL 1-4 containment. These cabinets are ideal for applications involving antineoplastic drugs, genetic materials, and other hazardous airborne particulates. All models are NSF-Listed, ensuring the highest standards of safety and performance.
Designed for flexibility, these Logic BSCs can exhaust HEPA-filtered air into the laboratory or through an exhaust system via the optional Ventus II Canopy Connection, making them suitable for applications involving small quantities of volatile toxic chemicals and trace amounts of radionuclides.
Logic Class II, Type B2 Biosafety Cabinets (BSCs) provide extensive protection for personnel, products, and the environment against hazardous particulates, including agents requiring BSL 1-4 containment. These Type B2 BSCs, often referred to as 100% Exhaust or Total Exhaust BSCs, maintain a minimum average airflow velocity of 100 feet per minute (fpm) through the sash opening and necessitate a dedicated exhaust system and remote blower for each cabinet. All models are NSF-Listed, ensuring compliance with the highest safety standards.
Type B2 BSCs draw HEPA-filtered downflow air from the laboratory and exhaust all inflow and downflow air into the atmosphere after HEPA filtration. This design makes these cabinets suitable for work involving volatile chemicals alongside microbiological applications, ensuring that all contaminated air passes through the exhaust HEPA filter before being discharged from the laboratory.
Cell Logic Class II, Type B2 Biosafety Cabinets (BSCs) are designed to provide comprehensive protection for personnel, products, and the environment from hazardous particulates, including agents requiring BSL 1-4 containment. These cabinets maintain a minimum average airflow velocity of 100 feet per minute (fpm) through the sash opening and require a dedicated exhaust system and remote blower for each cabinet. They are specifically tailored to meet the needs of cell research, featuring a modified sash for accommodating microscopes and a temperature-controlled work area to maintain cell viability.
Type B2 BSCs draw HEPA-filtered downflow air from the laboratory and exhaust all inflow and downflow air into the atmosphere after HEPA filtration. This design ensures robust safety for critical operations, as no air is recirculated, making them suitable for work involving volatile chemicals in conjunction with microbiological applications.
The Logic Vue is a specialized Class II enclosure designed to maximize protection and containment for large instruments such as liquid handlers, flow cytometers, and other automated equipment. It provides laminar, unidirectional ISO 5 air for product protection and meets or exceeds NSF/ANSI Standard 49 testing criteria for both product and personnel safety. High visibility windows on all sides allow unobstructed viewing of the stainless steel interior, while dual full-open 42" sashes in the front and rear facilitate easy access to instrumentation.
Powered by MyLogic™ OS with Constant Airflow Profile™ technology, the Logic Vue ensures user safety by displaying alerts, filter life, and more. It also features a reinforced work surface, safety interlock for automated equipment, 16 pass-throughs, ample knee space, and access ports, allowing for safe and seamless automation in the lab.
The Axiom Class II Type C1 is designed to maximize safety and flexibility, being the first biosafety cabinet that can operate in a recirculating Type A mode for standard microbiological work or connect to an exhaust system to function in Type B mode for handling hazardous chemicals. Its unique design includes the Chem-Zone™, which provides a clearly defined area for chemical safety, ensuring peace of mind when handling chemicals. Additional features include ergonomic Inclination™ Technology and the intuitive MyLogic™ Operating System for ease of use.